Investigation of Voltage-programmed and Current-programmed Asymmetrical Half-Bridge

YANG Zhong-wang,JIN Tian-jun,L(U) Zheng-yu
DOI: https://doi.org/10.3969/j.issn.1000-100x.2007.09.017
IF: 5.967
2007-01-01
IEEE Transactions on Power Electronics
Abstract:Researches about asymmetrical half-bridge review that there are four poles and three zeroes under voltage control mode,which makes it hard to compensate the system steady under high crossover frequencies.But little work had been done about using current control mode in asymmetrical half-bridge.The principle and small-signal mode of asymmetrical half-bridge under voltage control mode are presented.The current control mode applied in asymmetrical half-bridge is also introduced.The small-signal mode will be analyzed,and at last there will be some comparisons between the voltage programmed control method and the current programmed control method used in asymmetrical half-bridge.
What problem does this paper attempt to address?