Application of Full-closed Loop Control Based on PMAC to Ultrasonic Testing

XU Zhi-nong,WANG Li-qiu,ZHANG Yang,YANG Chen-long
DOI: https://doi.org/10.3969/j.issn.1671-7848.2010.06.030
2010-01-01
Abstract:The ultrasonic testing method of complex surface shape is studied.The traditional half-closed loop control method can not eliminate the error in the dive link,so it is difficult to scan the defects less than 1.2 mm in the material.To improve the accuracy of the system,an encoder is added on the load to form a full-closed loop control system.By the encoder,the actual position of the load is feed back to the controller achieve the real-time error compensation and improve the motion accuracy.The modelling of the full-closed loop control system is given,and the dynamic response curves are gotten using Matlab.The simulation shows that the full-closed loop control system can reduce the error and delay in the dive link.The half-closed loop control system and the full-closed loop control system are used to scan the same propeller blades of the plane separately.The result shows that full-closed loop control system can reduce the positioning error from 15.43 μm to 9.51 μm,and the probability of defects misjudgment from 8.3 % to 3.2%.