Power Maximised and Anti‐saturation Power Conditioning Circuit for Current Transformer Harvester on Overhead Lines

Zhongnan Qian,Jiande Wu,Xiangning He,Zhengyu Lin
DOI: https://doi.org/10.1049/iet-pel.2018.5389
IF: 2
2018-01-01
IET Power Electronics
Abstract:The current transformer (CT) harvester is effective and efficient for energy harvesting on overhead lines due to its higher reliability and power density compared to other techniques. However, the current of overhead conductor fluctuates from tens of to thousands of amperes, which brings two challenges for the CT harvester design. First, the startup current, above which the harvester can independently power the monitoring devices, should be as low as possible, so that the battery capacity can be reduced; second, the magnetic core should be ensured unsaturated in high current condition. This study proposes a power conditioning circuit with comprehensive control to maximise the output power and prevent the core from saturation. A prototype that can deliver 22.5W power with 200A is designed, and a control strategy based on the finite-state machine is implemented. Experimental results show that the startup current for 2W load is about 30A, and the core power density at 60A is 45.96mW/cm(3), both of which are markedly improved compared to the reported results of the same condition.
What problem does this paper attempt to address?