The ESR Signals in Different Minerals and the Bleaching of Feldspar
Weili Bi,Chaolu Yi,Haijun Yang,Xiangke Xu,Gang Hu
DOI: https://doi.org/10.3390/min13081108
IF: 2.5
2023-01-01
Minerals
Abstract:The use of quartz is critical to the electron spin resonance (ESR) dating of sediments and fault gouges. The germanium center (Ge center) in quartz is a commonly used color center employed in ESR signal measurement. Although Ge center signals in quartz can be detected using an ESR spectrometer, they are weak and sometimes undetectable. Impurities in quartz grains can further aggravate these deficiencies and may even invalidate any attempt to repeat ESR ages due to the deficiencies evident in the processes used in sample preparation. Using sieving, carbonate-organic matter removal, water flotation, magnetic separation, heavy liquid separation, and HF solution etching, we separated quartz, feldspar (plagioclase), mica, and the heavy minerals and measured the ESR signal in each of them to examine the impact of impurities within mineral grains on the ESR signals. From the ESR spectra, we observed intense ESR signals in feldspar and the heavy minerals and weak signals in mica at the same positions as the Ge center in the quartz. The ESR signals in the feldspar proved to be the most intense and overrode the peaks exhibited by the Ge center in the quartz. Feldspar is commonly associated with quartz in sediments, but it is difficult to separate it from quartz as their colors, specific gravities, and magnetic properties are similar. Any ESR signal in quartz containing foreign minerals would therefore be likely to be heavily disturbed by the signals from these foreign minerals, particularly from the feldspar and heavy minerals. ESR signals in the feldspar decreased similarly to those in the quartz when exposed to sunlight, declining by 70%–80% after being exposed for 50 h. Such declination was more obvious in high-altitude areas than in low-altitude areas. Our results indicate that highly pure quartz is required when dating; we would therefore strongly suggest that the procedures for the purification of quartz grains should include floating, heavy liquid separation, and HF solution etching to remove the feldspar, heavy minerals, and any remnant magnetite. Such a procedure would guarantee that the signal that is measured comes from the quartz alone, allowing repeatable measurements using the same spectrometer as well as valid comparisons between the spectrometries derived from different spectrometers.