Monitoring of structural modal parameters and dynamic responses of a 600m-high skyscraper during a typhoon
Yinghou He,Q. S. Li,Hongping Zhu,Xuliang Han,Y.C. He,Xiao Li
DOI: https://doi.org/10.1002/tal.1456
2018-01-01
Abstract:This paper presents field measurement results of structural dynamic properties and wind-induced responses of 600m-high Ping-An Finance Center in Shenzhen during the passage of Typhoon Haima. The field measurements included wind speed, wind direction, and structural acceleration responses during the typhoon. Analysis of the field measurements is carried out to investigate the wind-induced structural vibrations and dynamic properties of the skyscraper under typhoon condition. In the analysis, natural frequencies and damping ratios of Ping-An Finance Center are estimated using Peak-Picking method, half-power bandwidth method in frequency domain, and random decrement technique in time domain, respectively. Two band-pass filtering methods, namely, elliptical filtering method and Kaiser-window FIR filter, are adopted to deal with the measured acceleration signals. Consequently, the modal parameters identified with the Peak-Picking, half-power bandwidth, and random decrement technique methods are presented and discussed in detail. In addition, the probabilistic characteristics of the recorded acceleration responses are analyzed using the generalized extreme value distribution, and then the serviceability of the skyscraper during the typhoon is evaluated.