Air infiltration rates in the bedrooms of 202 residences and estimated parametric infiltration rate distribution in Guangzhou, China

Pok Lun Cheng,Xiaofeng Li
DOI: https://doi.org/10.1016/j.enbuild.2017.12.062
IF: 7.201
2018-01-01
Energy and Buildings
Abstract:•Air infiltration rates in 202 bedrooms using natural ventilation were measured in Guangzhou, China.•Over 80% of the measured bedrooms didn't satisfy the Chinese building code for minimum ventilation rate.•The air infiltration rates are log-normally distributed (R2 = 0.85), ranging from 0.05 to 1.32 h−1, with an arithmetic mean of 0.41 h−1.•The air infiltration rate distribution can be used in analyzing cooling energy consumption and indoor air quality from outdoor pollution in natural ventilated residential buildings in south China.