MHD Pressure Drop Measurement of PbLi Flow in Double-Bended Pipe

Shoki Nakamura,Tomoaki Kunugi,Takehiko Yokomine,Zensaku Kawara,Koji Kusumi,Akio Sagara,Juro Yagi,Teruya Tanaka
DOI: https://doi.org/10.1016/j.fusengdes.2017.12.009
IF: 1.905
2017-01-01
Fusion Engineering and Design
Abstract:The design of liquid metal cooling system for the liquid blanket concepts in magnetic fusion reactor requires the magnetohydrodynamics (MHD) friction loss coefficients for various pipes including pipes and bents to estimate the pressure drop of the whole blanket. The aim of this study is to reveal the MHD pressure drop of PbLi flow in a double-bended pipe. The experiments were conducted in the Oroshhi-2 loop having a super conducting magnet of 3T at NIFS in Japan. In this paper, the MHD pressure drops of the pipe under the magnetic field of 0.5T-3.0T, the ranges of Reynolds number (Re) of 2000-200,000 and Hartmann number (Ha) of 106-640 at the upstream, double-bended and downstream regions were measured. As the results, all the MHD friction loss coefficients in three regions were well correlated with the interaction parameter (Na = Ha(2)/Re) in the range of 0.1 < N < 100. Finally, the correlation equations of MHD friction loss coefficient against the interaction parameters at the upstream, double-bended and downstream regions of the pipe were obtained. Moreover, it was briefly discussed on the implementation to the liquid metal cooling system design for fusion reactor.
What problem does this paper attempt to address?