Energy Impact of Air Pre-cooling on Screw Air Compressor

Da Guo,Zhixian Ma,Jili Zhang,Mingsheng Liu
DOI: https://doi.org/10.1016/j.proeng.2017.10.147
2017-01-01
Procedia Engineering
Abstract:Air compressors are widely used in a variety of industries. The energy consumed by air compressors comprises a significant portion of the overall energy consumption in industrial plants. Both theoretical and experimental studies were conducted to investigate the impacts of air pre-cooling on the energy consumption of air compressor. Experiments were performed on a 11 kW screw air compressor. The paper presents the details of the modelling as well as the measured results. The results indicate that the energy consumption decreases by 0.65% for every 1℃ drop in suction temperature. The energy consumption decreases 0.243% for every 1% drop in suction relative humidity. Significant compressor energy consumption can be reduced by pre-treating or pre-cooling suction air.
What problem does this paper attempt to address?