Optimization Of Metal Anode Layer For Transmission Anode Flat Panel X-Ray Source Using Zno Nanowire Feas

Kun Wang,Daokun Chen,Yuan Xu,Guofu Zhang,Zhipeng Zhang,Keshuang Zheng,Juncong She,Shaozhi Deng,Ningsheng Xu,Jun Chen
DOI: https://doi.org/10.1109/IVNC.2017.8051655
2017-01-01
Abstract:A transmission anode flat panel X-ray source with the ZnO nanowire field emitter arrays(FEAs) has been realized. The thickness of the transmission-type flat panel X-ray target has been optimized to maximize the output intensity of X-rays. The EGSnrc-based Monte Carlo codes are utilized to simulate the Xray intensity and spectrum generated from the target. The simulation results show that the target thickness is important factor affecting the output X-ray intensity. Tungsten film anodes of different thickness were prepared and tested in a transmission anode flat panel X-ray sources using the ZnO nanowire FEAs under 20kV anode voltage. A figure of merit is introduced to characterize the output intensity of X-ray under unit electron number. The experimental results agreed with the simulating results and the obtained optimal thickness of tungsten film is about 380nm.
What problem does this paper attempt to address?