Dosimetry of CT Guidance I-125 Seed Implantation for Pelvic Recurrent Rectal Cancer Assisted by 3D Printing Individual Noncoplanar Templates

H. Wang,J. Wang,Y. Jiang,S. Tian,Z. Ji,F. Guo,H. Sun
DOI: https://doi.org/10.1016/j.ijrobp.2017.06.1070
2017-01-01
Abstract:To analyze the difference of dosimetric parameters between pre-plan and post-plan of 125I radioactive seed implantation assisted by 3D printing individual non-coplanar template ( 3D printing template) for locally recurrent rectal cancer (LRRC). From February 2016 to December 2016, 17 patients with locally recurrent rectal cancer received 125I seeds implantation under CT guidance assisted by 3D printing template in our center. Each patient underwent CT simulation, three-dimensional treatment planning pre-implantation, 3D printing template design, radioactive seed implantation assisted by 3D printing template and dosimetric verification post implantation. The median activity of seed was 0.63 mCi (0.56 to 0.7 mCi), and the median number of seeds was 82 (19 to 192). D90, D100, V100, V150, CI, EI, HI, D5cc, D2cc of bladder and bowel of pre-plan and post-plan were calculated, respectively. Paired t test was used to evaluate the difference of dosimetric parameters between pre-plan and post-plan. The median D90 of pre-plan and post-plan were 13890.1 cGy and 13879.6 cGy, respectively. The median D100 of pre-plan and post-plan were 5339.5 cGy and 5421.9 cGy, respectively. The median V100 of pre-plan and post-plan were 90.0% and 90.0%, respectively. The median V150 of pre-plan and post-plan were 63.6% and 62.1%, respectively. The median CI of pre-plan and post-plan were 0.71 and 0.64. The median EI of pre-plan and post-plan were 0.23 and 0.28, respectively. The median HI of pre-plan and post-plan were 0.28 and 0.30. The median bladder D5cc of pre-plan and post-plan were 2028.0 cGy and 2541.6 cGy, respectively. The median bladder D2cc of pre-plan and post-plan were 3098.8 cGy and 4140.4 cGy, respectively. The median bowel D5cc of pre-plan and post-plan were 5124.9 cGy and 6353.7 cGy, respectively. The median bowel D2cc of pre-plan and post-plan were 7254.5 cGy and 7875.7 cGy, respectively. 3D printing template might be helpful for locally recurrent rectal cancer patients who receive 125I radioactive seed implantation assisted by 3D printing individual template, seed implantation might have more chances to achieve prescription dose and dose limitation of organs at risk of pre-plan, which is important for precise implantation and quality control.
What problem does this paper attempt to address?