Catalytic Degradation of Tetracycline by Mo-Fe Catalyst

Suli Zhi,Liang Tian,Nan Li,Keqiang Zhang
DOI: https://doi.org/10.5004/dwt.2017.20937
IF: 1.1
2017-01-01
Desalination and Water Treatment
Abstract:Incorporating Mo into Fe-catalyst can enhance the catalytic activity and application range of pH value of catalyst. Therefore, Mo-Fe compounds with different Mo: Fe molar ratios were prepared by a wet chemical process, and then were used to degrade tetracycline (TC) by initiating a heterogeneous Fenton-like system with H2O2. The results demonstrated that the Fe-2(MoO4)(3)/H2O2 system most efficiently degraded TC. At an initial concentration of 50 mg/L TC with natural pH value (about 5.5), about 99% of TC could be removed within 30 min by 0.8 g/L Fe-2(MoO4)(3) and 17.6 mM H2O2 at 299.15 K. Moreover, the pH value did not affect TC removal rate; but changed the total organic carbon removal rate. The Fe leaching concentration was about 0.009 mg/L under the optimal conditions. The TC removal rates in the Fe-2(MoO4)(3)/H2O2 system were influenced by the complexity level of practical wastewater. The scavenging experiment using several scavengers indicated that both hydroxyl radicals (in solution and catalyst surface) and superoxide radicals played important roles in the degradation of TC. A possible degradation mechanism and pathway for TC were proposed in the Fe-2(MoO4)(3)/H2O2 system. Finally, a comparison was made between this study and some others, showing that Fe-2(MoO4)(3)/H2O2 was a preponderant system for TC removal.
What problem does this paper attempt to address?