Heat Transfer Performance of Aviation Kerosene RP-3 Flowing in a Vertical Helical Tube at Supercritical Pressure

Jie Wen,Haoran Huang,Yanchen Fu,Guoqiang Xu,Kun Zhu
DOI: https://doi.org/10.1016/j.applthermaleng.2017.04.055
IF: 6.4
2017-01-01
Applied Thermal Engineering
Abstract:Convective heat transfer characteristics of aviation kerosene RP-3 at supercritical pressure (P = 5 MPa) in vertical helical tube were experimentally studied. The helical tube has 1.82 mm equivalent inner diameter, 20 mm helical diameter and 10 mm pitch. Circumferential temperatures were detected at both upward and downward flow experiments and the results indicated that: The secondary flow induced by centrifugal force moves outward of the cross section and inside temperature is larger than the outside. Thus, the outside heat transfer coefficient (HTC) is averagely 31.5% larger than that of the inside. Furthermore, heat transfer enhancement leading by centrifugal secondary flow is the key factor when the Richardson ratio is larger than 10. At last, two correlations of Nusselt number are developed to predict heat transfer of aviation kerosene RP-3 in helical tube based on experimental data at supercritical pressure. (C) 2017 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?