Heat-transfer Distribution Optimization for the Heat-Integrated Air Separation Column
Zhiyu Wang,Weizhong Qin,Chunhua Yang,Wenhai Wang,Shenghu Xu,Weihua Gui,Youxian Sun,Daoxiong Xie,Yalin Wang,Jiangang Lu,Qiquan Chen,Xinggao Liu
DOI: https://doi.org/10.1016/j.seppur.2020.117048
IF: 8.6
2020-01-01
Separation and Purification Technology
Abstract:The heat-integrated air separation column (HIASC) is an advanced energy-saving technology for the cryogenic air separation process, although a large capital investment is required for installed heat exchangers. These heat exchangers have a location-dependent effect upon the separation which leaves room for optimization. This paper, therefore, aims to optimize the heat-transfer distribution of HIASC regarding minimum heat exchanger costs while maintaining the low energy consumption level. Results indicate that the heat-transfer tends to concentrate at both ends of the column. The influence of operational parameters is further studied by the idea based on the liquid-vapor ratio. Finally, an optimal HIASC with respect to the minimal heat exchanger investment is obtained, and the heat exchanger costs are reduced by 44.4% compared with the uniform distribution with a similar energy-saving level.