Adaptive Generic Model Control Scheme for an Optimized External Heat Integrated Air Separation Column using Unscented Kalman Filter

Hamedalneel Babiker Aboh Hamid,Xinggao Liu
DOI: https://doi.org/10.1016/j.cep.2024.109956
IF: 4.264
2024-08-25
Chemical Engineering and Processing - Process Intensification
Abstract:An External Heat-Integrated Air Separation Column (E-HIASC) process is a promising air separation technology. This study focuses on the operational stability of the optimized E-HIASC process for separating nitrogen, oxygen, and argon mixtures. The operation stability of process is achieved through an Adaptive Generic Model Control (AGMC) scheme which is designed by incorporating the identified E-HIASC state-space dynamic model into the controller algorithm. The controller synthesizes the Generic Model Control (GMC) algorithm, decoupled ARX model, and Unscented Kalman Filter (UKF) algorithm to enable the auto-regression and exogenous (ARX) for model identification and the UKF algorithm to estimate time-varying parameters and compute unmeasured E-HIASC state parameters required in the GMC algorithm. A Generic Model Control (GMC) and Multivariable PID (M-PID) control schemes were also designed for benchmarking study. Simulation results show that an optimal E-HIASC process improved the energy efficiency and reduced the capital investment compared to its internal heat integrated counterpart. Likewise, the AGMC scheme performs better than the GMC and M-PID schemes in tracking the product concentration set point and disturbances rejection.
energy & fuels,engineering, chemical
What problem does this paper attempt to address?