An optical sensor for hydrogen sulfide detection in open path using WMS-2 f /1 f technique

Li-mei Song,Li-wen Liu,Yan-gang Yang,Qing-hua Guo,Jiang-tao Xi
DOI: https://doi.org/10.1007/s11801-016-6170-7
2016-01-01
Optoelectronics Letters
Abstract:An optical hydrogen sulfide (H 2 S) sensor based on wavelength modulation spectroscopy with the second harmonic (2 f ) corrected by the first harmonic (1 f ) signal (WMS-2 f /1 f ) is developed using a distributed feedback (DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H 2 S line at 6 336.62 cm -1 in the fundamental absorption band of H 2 S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2 f /1 f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s (in concentration range of 15.2—45.6 mg/m 3 ), respectively. The maximum relative deviation for continuous detection (60 min) of 30.4 mg/m 3 H 2 S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m 3 with optimal integration time of 32 s. The optical H 2 S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields.
What problem does this paper attempt to address?