Lithium Salt Inclusion As a Strategy for Improving the Li+ Conductivity of Nafion Membranes in Aprotic Systems

Liuqing Yang,Jie Zeng,Bo Ding,Chaohe Xu,Jim Yang Lee
DOI: https://doi.org/10.1002/admi.201600660
IF: 5.4
2016-01-01
Advanced Materials Interfaces
Abstract:Though popular in polymer electrolyte membrane fuel cells and vanadium redox flow batteries, Nafion membranes are rarely used in lithium batteries because of their poor Li+ conductivity in aprotic solvents. The performance of Nafion membranes in aprotic systems can however be improved by the following procedures: H+/Li+ exchange, membrane swelling, and contraction in selected aprotic solvents to implant lithium perchlorate (LiClO4) into the membrane interior. A Nafion membrane prepared as such, and containing 7.15 wt% of dispersed LiClO4, can have a Li+ conductivity as high as 1.22 × 10−3 S cm−1 in propylene carbonate, and 2.6 × 10−4 S cm−1 in an ethylene carbonate/dimethyl carbonate mixture at room temperature. The inclusion of LiClO4 also increases the tensile strength of Nafion 117 membrane by 123.7% and decreases the permeabilities of ferrocene and 1,1′‐dibromoferrocene, the common mediators for redox‐flow Li‐ion batteries, to 9.43 × 10−7 and 1.50 × 10−5 cm2 h−1, respectively, to deliver a good performance in an experimental flow cell.
What problem does this paper attempt to address?