Performance of Fluoride Electrosorption Using Micropore-Dominant Activated Carbon As an Electrode

Yingzhen Li,Yanping Jiang,Ting-Jie Wang,Chang Zhang,Haifeng Wang
DOI: https://doi.org/10.1016/j.seppur.2016.08.043
IF: 8.6
2017-01-01
Separation and Purification Technology
Abstract:Fluoride electrosorption using micropore-dominant activated carbon (AC) as an electrode was developed. The parameters of voltage, flow rate, and electrode gap were optimized to be 1.6 V, 10 mL/min and 2 mm, respectively. The electrosorption isotherm conforms to the Langmuir model, indicating the monolayer adsorption of the fluoride ions. The saturated electrosorption capacity for fluoride ions under the optimized parameters was 16.8 mg/g (AC). The high saturated electrosorption capacity of this microporedominant AC was attributed to its high specific surface area of 2130 m(2)/g, which was mainly contributed by the micropores. The saturated electrosorption capacity has a linear relationship to the square of the applied voltage. The fluoride electrosorption occurred only when the voltage was higher than the electro-capillary maximum voltage of 0.14 V for this AC. The charge efficiency reached a high value of 0.98 for the micropore-dominant AC, indicating that only counterions existed in the micropores. (C) 2016 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?