Lmi-Based Direct Grid Current Robust Guaranteed Cost Control Of Grid-Connected Inverters With Lcl Filters For Weak Grid

Yu Wang,Yaoqin Jia,Xumeng Yan
DOI: https://doi.org/10.1109/IPEMC.2016.7512374
2016-01-01
Abstract:This paper presents a direct grid current robust guaranteed cost controller (DGCRGCC) which combines regional pole placement technique and H-2 performance criteria based on linear matrix inequalities for LCL-filtered grid-connected inverters. The obtained controller guarantees damping of the LCL filter resonance and robust stability and an upper bound on the H-2 performance of the closed-loop system under uncertain and time-varying grid impedance. In order to ensure zero steady-state error tracking of the grid current and rejection of the grid voltage background harmonics, resonant controllers are taken into account as a cascade compensator. Simulation and experimental results from a 9.1-kW three-phase grid-connected inverter validate the effectiveness of the proposed methods.
What problem does this paper attempt to address?