Shock Tube Study of Ignition-Delay Measurements and Kinetic Mechanism Research for Syngas
Dong He,Yanjun Ding,Xiaohe Xiong,Shuo Shi,Yanjun Du,Zhimin Peng,Weiping Yan
DOI: https://doi.org/10.2514/1.b36722
2018-01-01
Journal of Propulsion and Power
Abstract:Ignition-delay times of syngas mixtures (H-2/CO/O-2/Ar) were measured using a shock tube in the following conditions: temperatures of 910-1290 K, pressures of approximately 1.0 atm, an equivalence ratio of 1.0, H2:CO ratios of 0.25 and 4.0, and especially Ar dilution rates of 94% and 79%. Simulating results and sensitivity analysis show that Davis Mech, NUIG Mech, and Varga Mech have more accurate computational results than GRI 3.0, SD Mech, and Li Mech at around 1000K because for reaction H+O-2(+Ar)=HO2(+Ar) the former three mechanisms have a lower reaction rate. Oxidation of H2 occurs mainly through reactions O+H-2=H+OH and OH+H-2=H+H2O, whereas CO+OH=CO2+H is the dominant reaction for the oxidation of CO. Comparative analyses of syngas with the same H-2:CO ratio at 94% and 79% Ar dilution rates show that heat absorption of Ar during combustion is the main cause of long ignition-delay time, although Ar also inhibits the reactivity of syngas through H+O-2(+Ar)=HO2(+Ar) at 1000 K. Moreover, the pressure response curve rises slowly with 94% Ar dilution but sharply with 79% Ar dilution under low-temperature conditions, and detonation (or deflagration to detonation) can be observed under such conditions. In addition, OH* emission was observed behind the incident shock wave when its velocity reached 1200m/s with 79% Ar dilution, and it was unable to measure ignition-delay time behind the reflected shock wave.