Analysis of the Electric Field Through Internal Gap of Electric Multiple Unit Roof Composite Insulator

Guangning WU,Kunsong YANG,Guoqiang GAO,Jixing SUN,Bowen ZHANG,Yunyun ZHAO
DOI: https://doi.org/10.13336/j.1003-6520.hve.2014.10.043
2014-01-01
Abstract:When a gas or liquid gap in the interface exists between the core rod and sheath of roof composite insulator, the electric field through the gap will be distorted. Meanwhile, partial discharges may easily be induced by the overvoltage in electric multiple units and hence intensify the aging and degradation of the units' interior insulation. To assess the influence of gap on electric field distribution, taking a real case of inner breakdown accident of roof insulator as an example, we established a three-dimensional multi-parameter finite-element model of busbar supporting insulator in ANSOFT MAXWELL, and calculated and analyzed the electric field through air or liquid gaps of different sizes at different locations. It is obtained that, compared with non-gap situation, the electric field at the gap location can be enhanced by 1.65 times, which can further initiate intense partial discharges. The concentration of ion is high in liquid gap, and when the conductivity of gap reaches 10-5 S/m, the electric field of outside gap may attain 49.3 kV/cm. With the gap's extension or the decrease of the distance from gap to the flange at high-voltage side, the damage to insulation inside insulator gets severer, and this turns quite obvious when the distance is less than 5 mm.
What problem does this paper attempt to address?