Abstract:AIM:To compare the apical transpositions of preparing curved root canals prepared using stainless steel K-file, nickel-titanium alloy K-file and X-file.METHODS:Forty-five extracted premolars with root canal curvature of 15~35 degrees determined by Schneider's method were divided into fifteen sections in curvature sequence. After that, three canals of each section were randomly distributed to three different instrumentational groups. The root canals were coronal preflared with Gates Glidden following by sequential preparation from #15 to #40 to working length. The standard digital radiographs were taken to record the position of the tip of the different sizes of instruments. At last, the apical transpositions of pre- and post-instrumentation were measured under stereomicroscope. RESULTS: The larger the files were, the greater the apical transpositions became. Between stainless steel K-file and two nickel-titanium alloy instruments, the apical transpositions of size #35 or #40 instruments were significantly different (P0.05) .Two cases of root perforations occurred in the stainless steel K-files group. The apical transpositions between the two groups of nickel-titanium alloy instruments were not significantly different (P0.05).CONCLUSION:The effect of nickel-titaniumalloy alloy instruments was superior to that of stainless steel instruments by comparing their apical transpositions of preparing curved root canals. [