The investigation and measurement on the pulverized coal combustion in tangentially-fired boiler

周萍,黄忠朗,周乃君,陈乔平,王强,全向东
DOI: https://doi.org/10.3969/j.issn.1004-3950.2001.05.008
2001-01-01
Energy Engineering
Abstract:To find the reason for the low heat efficiency of pulverized coal boiler with 130t/h and melt slag produced on the vapourizing surfaces, the flowing field of isothermal gas and the parameters for heat engineering in boiler is measured. Furthermore, the flowing field and combustion of pulverized coal and heat transfer are modeled numerically by using k e g turbulence combustion model for gas phase and two competing reactions models for the coal devolatilization. The results in simulation are agreement with that in measurement on isothermal and thermal conditions. According to the results, the air excess factor in boiler furnace causes low heat efficiency. The great difference of air velocity between four burners on the same level results in that the real tangential circle promoted by the air stream departs from the furnace center, the flame brushes vapourzing surface and melt slag is produced on it.