The Position Study of the Projection Point of the Lumbar Pedicle Axis on the Posterior Aspect by Reconstructed CT

李兵,姜保国,傅忠国,张殿英,杜湘珂,王天兵
DOI: https://doi.org/10.3969/j.issn.1004-406x.2003.09.012
2003-01-01
Abstract:Objective:To establish the best starting point for fixing a pedicle screw to the axial center of the pedicle,which promotes safety and accuracy of transpedicular procedures.Method:A total of200vertebrae from L1~L5of40Chinese people were scanned on a GE LightSpeed QX/i computerized tomographic scanner in the axial plane.After images were reconstructed,the coordinates including the distance from the projection point of the lumbar pedicle axis to the midline of back(x)and to the midline of transverse process(y)were measured.Result:X coordinates increased from L1to L5,which showed male was longer than female(P0.05).The average of y coordinates stepped down from L1to L4where it was very close to mid-transverse process.But y was up to L5.Most of y coordinates were above mid-TP(transverse process),where as the variance was considerable.As far as y was concerned,there was significant difference between projection point and traditional position ways.Conclusion:Mid-TP was thought as an important landmark during the transpedicular procedures.But the projection point of lumbar pedicle is not in mid-TP.There are diversity in different person and segments,which become the main issue of high misplace rates.The coordinates of projection point of lumbar pedicle axis obtained individually from reconstructed CT images preoperatively could ensure utmost safety and accuracy of transpedicular procedures.
What problem does this paper attempt to address?