An Analysis of LIF Spectrum for Detecting Colorectal Carcinoma in Vivo and in Vitro

盛剑秋,晨智敏,高革,李世荣
DOI: https://doi.org/10.3760/cma.j.issn.1007-5232.2001.05.008
2001-01-01
Abstract:Objective To study the correlativity of laser-induced fluorescence (LIF) spectrum on the same specimen of colorectal carcinoma both in vivo and in vitro and to obtain the best diagnostic parameter in detecting colorectal carcinoma. Methods LIF spectra were analyzed from 10 patients with colorectal carcinoma during colonoscopy, and then analyzed again after resection. The cancer foci and normal mucosa more than 5 cm apart from the foci were excited by a nitrogen laser (337 nm)using a quartz optical fiber in gentle contact with the area of interest, and then the fluorescence emission was collected by the same quartz optical fiber. The LIF spectrum was analyzed using an optical multichannel analyzer (OMAⅢ). Results (1)The LIF spectrum from cancer tissues was same as that of normal tissues, both showed the main and the second peak respectively located at about 460 nm and 390 nm in vivo and in vitro. The main peak intensities in vivo from both cancer and normal tissue were significantly lower than these in vitro. The main peak intensities in vivo and in vitro from cancer tissue were decreased about 1 time to those from normal tissue.(2) The integrated spectral intensity in vivo and in vitro of cancer tissue from each patient was significantly lower than that from the corresponding normal tissue respectively, P 0.01; (3) The mean wave lengthes of main peak from cancer tissue in vivo and in vitro were shifted to the red fluorescence with 6 nm and 3 nm respectively compared with these of normal tissue; (4) The peak intensity ratios of the main peak (460 nm) to the second peak (390 nm) from cancer tissue both in vivo and in vitro were higher than those from normal tissue respectively, P 0.001; Conclusion Our findings demonstrated that the LIF spectroscopic features of colorectal cancer tissues are markedly different from those of the corresponding normal tissue, and suggested that the pattern of LIF spectra from cancer tissue in vivo was transformed essentially in accordance with that in vitro, the intensities of LIF spectra in vivo cancer tissue and normal tissue was lower than that in vitro. The integrated spectrally intensity or the main peak intensity, together with the wave length of main peak or the intensity ratios of the main peak to the second peak can improve the sensitivity for LIF spectra in discriminating cancer tissue from normal tissue.
What problem does this paper attempt to address?