A Novel Harmonics and Reactive Power Detection Method Based on Time Domain for Shunt Active Power Filter

李红雨,卓放,雷万钧,吴隆辉,王兆安
DOI: https://doi.org/10.3969/j.issn.1003-3076.2004.03.005
2004-01-01
Abstract:A novel current detection algorithm based on time domain for a three-phase shunt active power filter to eliminate harmonics and/or to correct power-factor and/or to balance the nonlinear unbalanced loads is presented and analyzed in this paper. This paper firstly presents the evaluation of the performance of three state-of-the-art current detection algorithms for active power filter. According to the complex power quality problems and various compensation purposes, such as harmonics elimination, special order harmonics elimination, reactive power compensation and fundamental negative-sequence current compensation, a novel current detection algorithm is presented. Comparing with other algorithms, this algorithm has the advantages of short time delay and clear physics concept. Different compensating current references can be obtained accurately and easily by adopting the presented algorithm. It ensures that the APF can achieve different compensation purposes well. Moreover, this algorithm is easy to be implemented in DSP. Experimental results are presented to validate the proposed algorithm.
What problem does this paper attempt to address?