Biomechanical Study on a New Peripheral Suture Method for Flexor Tendon Repair

王斌,汤锦波,顾剑辉,龚炎培,谢仁国,谭军,徐燕
DOI: https://doi.org/10.3760/cma.j.issn.1671-7600.2004.02.017
2004-01-01
Abstract:Objective To evaluate the biomechanical properties of a new pe ripheral suture technique that was designed by us. Methods Thirty-six porcine f lexor profundus tendons were harvested in zone Ⅱ from adult pig toes and divid ed into four groups. Each group of the tendons were repaired by one of the follo wing peripheral suture techniques: Running, Cross-stitch, Halsted and our newly developed method. All the tendons were pulled to complete failure by an Instron tensile testing machine. 2-mm gap formation force, failure load and energy to failure were investigated and compared among the groups. Results The newly devel oped peripheral suture showed the greatest tensile strength among the groups wit h 2-mm gap formation force at (53.2±6.0) N, failure load at (68.8±6.9) N, a nd stiffness at (6.6±0.7) N/mm. Its energy to failure was (0.784±0.075) J, whi ch was similar to that of Halsted method, but superior to those of Running and C ross-stitch methods. Conclusions The newly developed peripheral suture is stro nger than currently used peripheral suture methods. The technique is recommendab le in repairing flexor tendons when early motion protocols are considered, espec ially when core suture could not be performed confidently.
What problem does this paper attempt to address?