The Changes of Tensile Strength and Ultimate Work at the Early Period of Flexor Tendon Repair:An Experimental Study

陈建海,姜保国,傅中国,张殿英,王天兵,张宏波,赵富强,魏光如
DOI: https://doi.org/10.3760/cma.j.issn.1005-054x.2004.02.020
2004-01-01
Abstract:Objective To investigate biomechanical characteristics of the digitorum profundus flexor tendon repaired by the modified Kessler or Tsuge technique at the early period of postoperation at cocks.Methods Forty-two Sanhuang cocks were divided into 2 groups: modified Kessler or Tsuge technique, with 21 in each. The right 2nd and 4th digitorum profundus flexor tendons were severed and repaired by the modified Kessler or Tsuge technique. The repaired tendons were harvested at 7 time points-immediately after repair, 1, 4, 7, 10, 14, 21 days after operation. Biomechanical meters including ultimate force, ultimate work were documented in biomechanical test. Results The ultimate force decreased significantly at 10th day and returned to normal at 14th day in the modified Kessler method group, but it decreased at 4th day and did not return to normal even at 21st day in the Tsuge method group. The tensile strength of failure in the Tsuge method was significantly higher than that in modified Kessler method immediately after repair 1, 7 days after operation. Compared with that immediately after the repair, it decreased obviously at postoperative 4 days (Tsuge group )and 7 days day (Kessler group), and it continued to decrease at 21 days after operation. Conclusion There is no similarity in biomechanical characteristics in two suture methods at the early stage after tendon repair. The energy needed to pull repaired tendons until rupture decreases increasingly after operation.
What problem does this paper attempt to address?