Optimization of the Scanning Protocol for Diffusion Tensor Imaging of Head

肖江喜,郭雪梅,王霄英,蒋学祥
DOI: https://doi.org/10.3321/j.issn:1003-3289.2003.11.003
2003-01-01
Abstract:Objective To search for the reasonable scanning protocol for diffusion tensor imaging in the clinical study of the head.Methods Diffusion tensor imaging of the head was performed in 20 healthy adult volunteers.Different parameters including slice thickness,b value and the number of the diffusion sensitive gradient direction were applied and their impaction on the quality of the images were compared.Results Slice thickness had the greatest impaction on the signal noise ratio of the images.Scans with higher b value revealed better contrast between gray matter and white matter in ADC map,but noise in FA map became greater.The more the number of the direction was,the greater the SNR was,but the longer the scanning time was.Conclusion Scanning with thickness of 3mm,b value 1000 s/mm 2 and 25 directions is the reasonable protocol in the clinical study of white matter.
What problem does this paper attempt to address?