The relation between the concertration of OPG and wear debris accumulation

王骏骅,赵建宁,王与荣,吴苏稼,周利武,曾晓峰,郭亭,包倪荣
DOI: https://doi.org/10.3969/j.issn.1008-8199.2004.04.005
2004-01-01
Abstract:Objective:To observe the concentration of osteoprotegerin (OPG) around the prostheses, and study the relationship between the concentration of OPG and the accumulation of wear debris. Methods:Interface tissues were obtained at three Delee-Charnley acetabular sections and seven Gruen-Amstutz femur sections in four revision total hip arthroplasty surgery. The tissues were prepared for immunohistochemical assays with goat-anti-human OPG antibodies for evaluatingt the concentration of OPG in each section.Data of wear debris accumulated in the tissue were compared among all sections to determine periprosthetic distribution characteristics of abrasive wear debris with electronic microscope. Results:Data showed that the 3 rd section of acetabulum having much higher accumulating level of wear debris than that of the 1 st and 2 nd sections, and black metal wear debris distributed extensively at sections 1 and 7 of femur sections, with a accumulating level significantly higher than of the other femur sections (P0.05). Immmunohistochemical results suggested far more positive cells at the section 3 of acetabulum than those at sections 1 and 2, and even more in sections 1,6 and 7 of femur than those at the others (P0.05). Conclusion:The concertration of OPG found and deposition of wear debris can affect the local content of OPG Ligand and OPG.
What problem does this paper attempt to address?