Significance of Postoperative Evaluation by CT after Endovascular Exclusion for Debakey Type Ⅲ Aortic Dissection

赵,景在平,赵志青,包俊敏,陆清声,冯翔,冯睿,黄晟,叶必远
DOI: https://doi.org/10.3321/j.issn:1003-3289.2001.08.014
2001-01-01
Abstract:Purpose To evaluate the significance of postoperative detection by CT after endovascular exclusion for Debakey type III aortic dissection. Methods Fifty-one consecutive patients with Debakey type III aortic dissection underwent endovascular stent-graft exclusion. The figure and position of the graft, the patency in the lumen, the existents of endoleaks and the change of the dissection were evaluated. Results An endoleak was revealed from the mid-portion of the graft by CTA seven days after procedure. Incomplete thrombosis in the false lumen was detected in four cases, and there were reflux from distal into the false lumen. Frame alteration of the stent was revealed in one case, but the patency maintained. No other abnormality was revealed. Conclusion The method of CT evaluation has the characteristics of multiple reconstruction ways, more information, accurate, be easy understanding, clear images, peri-vessel tissue can be revealed, complications be easily detected. It can be used as the first-choice method in post-operation evaluation.
What problem does this paper attempt to address?