Technique of Endovascular Repairing after Prosthesis Bypass in the Treatment of Complex DeBakey Ⅲ Aortic Dissection

Wu Zhiyong,Xia Jun,Wang Zhiwei,Ou Jiale,Xu Peng,Li Luocheng
DOI: https://doi.org/10.3969/j.issn.1673-548X.2012.02.045
2012-01-01
Abstract:Objective To summarize the clinical experience of endovascular repairing combined with the prosthesis by-pass in the treatment of complex DeBakey Ⅲ aortic dissection.Methods In December 2010,2 male patients with complex DeBakey Ⅲ aortic dissection received endovascular repairing combined with the prosthesis by-pass.The patients were from 51 to 70 years old,averaged 60.5 years.Preoperative CTA found that the distances between breach and left subclavian artery openings were all less than 15mm,one of which tears in the left subclavian artery root.Aortic dissection was reversely stripping extended to aortic arch on different degree.On this way,neck arteries were reconstructed,and then endovascular repairing was completed in 12 hours.Results All patients successfully recovered from surgery procedure and were discharged from hospital in two weeks.Before discharge CTA indicated smooth blood-stream in prosthesis,no inner-leat and no endo-stent dislocation.Two cases followed-up for two months complainted no discomfort.Conclusion Endovascular repairing combined with prosthesis by-pass was a safe and effective method for complex DeBakey Ⅲ aortic dissection with the entry tear close to the left subclavian artery openings.