Clinical application of electron beam computed tomography in endovascular graft exclusion for thoracic aortic dissection

郑敏文,左健,孙立军,葛雅丽,赵宏亮,白桂琴
DOI: https://doi.org/10.3969/j.issn.1000-0313.2003.02.004
2003-01-01
Abstract:Objective:To investigate the clinical application value of electron beam tomography in endovascular graft exclusion for thoracic aortic dissection.Methods:5 cases of Stanford type B aortic dissection underwent electron beam computed tomographic angiography pre and postoperation with continuous volume scanning mode.The distance between intima dissection and subclavian artery and other important diamters were measured.Three dimentional reconstruction techniques as maximum intensity projection(MIP),curved planar reformation(CPR) and volume rendering technique(VRT)were used.Results:The stent grafts according to the parameters obtained by EBCT prior EVGE procedure matched perfectly to the need of inplantation.All stent grafts were placed in the true lumen and an enlargement of the lumen was observed in postoperative follow up.The false lumen decreased in size and thrombosis formation was observed.Conclusion:EBA provides accurate preoperative parameters and non invasive postoperative follow up.EBCT is more useful than other examination techniques in clinical application.