Finite Element Analysis of Allogeneic Bone Plates Combined with Different Screw in the Treatrment of Femoral Shaft Fractures

吴泽海,王永清,董黎敏,周星衡,叶金铎,李毅,毕红宾
DOI: https://doi.org/10.13795/j.cnki.sgkz.2014.10.012
2014-01-01
Abstract:Objective To comparative analysis of two different screws allogeneic bone plate in the treatment of femoral fracture stress distribution,and to provide the mechanical basis for the clinical. Methods CT images of femur were obtained from spiral ct,which were subsequently imported into mimics software according to DICOM standard,and then built a three-di-mensional model of the femur. Built bone plates model and screws model(simplified cylinder)in proe 5. 0 and then importing into ansys12. 0 meshed and assigned with material properties after assembly was completed. And applying 700N axial load,15 N·M bending load,15 N·M torsional load. The maximum value of 6 absorbable screw's maximum principal stress is 5. 75 Mpa,of 6 titanium screws is 24. 9 Mpa under the three load. Two different screws,the stress distribution of the femur and the bone plate is substantially the same. Conclusion Absorbable screw adapted to allogeneic bone plates fixation,compared with titanium screws,has the advantage of reducing the bone screw holes at the stress shielding.
What problem does this paper attempt to address?