Biomedical analysis of four fixation systems in treatment of type II traumatic spondylolisthesis of the axis: a finite element analysis

Zuoyao Long,Hailong Yu,Huifeng Yang,Mingming Guo,Lingzhi Meng,Hong Yuan,Liangbi Xiang,Qi Wang
DOI: https://doi.org/10.1007/s11517-023-02981-1
Abstract:This study aimed to compare the properties and safety of self-designed plates in type II traumatic spondylolisthesis of the axis with those of traditional devices via finite element (FE) analysis. We constructed a hangman's fracture FE model from the occipital bone (C0) level to the C3 level. Then, FE models were constructed for the following four fixation systems: an anterior cervical L-shaped plate with four vertebral screws (4-ACLP), or six screws (6-ACLP), an anterior cervical orion plate (ACOP), and a posterior fixation system. A preloaded compressive force of 50 N and a moment of 1.5 N·m were applied to each model under six working conditions. The mobility of the C2/3 segment decreased significantly in four fixation models. In the Mises stress cloud diagram, 4-ACLP showed a better stress distribution in both the bone graft and fixation system than 6-ACLP and ACOP. The resultant force of 4-ACLP was lower but higher than ACOP in axial force. Additionally, the cage in the 4-ACLP configuration experienced the highest stress in the six working conditions. Hence, this novel self-designed plate has the potential to mitigate the operational difficulties, provide sufficient stability, reduce the risk of plate or screw fractures, and improve bone fusion.
What problem does this paper attempt to address?