Design Criterion for Cylinder Head Water-Jacket Based on Boiling Heat Transfer Model

Xiao-ri LIU,Guo-xiang LI,Yu-ping HU,Song FU,Kang-yao DENG
DOI: https://doi.org/10.13949/j.cnki.nrjgc.2014.04.015
2014-01-01
Abstract:Five kinds of zones were defined by possibly existing heat transfer conditions and their characteristics:forced convection(FC) zone,partially developed nucleate boiling(PDNB) zone,fully developed nucleate boiling(FDNB) zone,zone of safety allowance for CHF(SAC),transition and film boiling(TFB)zone.In consideration of model error and water-jacket heat transfer safety allowance,the design criterion for cylinder head water-jacket was proposed.Software module of heat transfer criterion in cylinder head waterjacket was developed and applied practical head water-jacket calculation of two kinds of engines.In a heavy duty commercial vehicle diesel engine,max.error between calculated and test results for the firedeck is3.19%and average error is 1.42%.It is demonstrated that this method can accurately reflect the actual head heat transfer situation.Application example in a compact diesel engine shows also that it is convenient to assess and improve head water-jacket design.
What problem does this paper attempt to address?