Study on Linearity Optimization of Insertion Electromagnetic Flowmeter

Li YI,Yun ZHU,Jian-ying ZHENG,Ha ZHENG
DOI: https://doi.org/10.3969/j.issn.1006-9348.2015.03.057
2015-01-01
Abstract:Research the improving methods for accuracy of insertion electromagnetic flowmeter. In theory,there is a completely linear relationship between input flow signal and output flow signal of insertion electromagnetic flowmeter. But in fact,insertion electromagnetic flowmeter can change the flow field and produce a nonlinear phenomenon after inserting the pipe because it can produce boundary layer on the probe surface. To improve this phenomenon,three-dimensional simulations were carried out with four different shapes of probes and FLUENT software,and a relatively good linearity probe shape was obtained through comparing linearity between the average flow rate and the measured flow rate. Simulation results show that improving the accuracy of the insertion electromagnetic flowmeter by optimizing the probe shape is an effective and feasible method and provides a theoretical foundation and technical support for the better development of insertion electromagnetic flowmeter.
What problem does this paper attempt to address?