Feasibility Study of Elbow Flowmeter Used in High Temperature Gas-cooled Reactor
Shao-feng LI,Yan-fei SUN,Gui-jun XUE,Shuo-ping ZHONG,Zhi LI
DOI: https://doi.org/10.3969/j.issn.2095-2716.2015.01.011
2015-01-01
Abstract:In order to the safe operation of nuclear power system with High Temperature Gas-cooled reactor (HTGR),Elbow flowmeter was designed to measure the flow rate of helium in the first loop.In the flow process,the helium flow into 14 pipelines which are mirror symmetric distribution,then aggregated into the junction box,re-turned to the reactor through the compressor.At the 4 pipelines of 14 pipelines,elbow flowmeter was designed to measure the branch flow rate,and the requirement to evaluate the total flow rate of high precision.Through the experimental method and numerical simulation method,we studied the flow distribution of 14 pipelines.The purpose is to determine the accurate relation between branch flow rate and total flow rate.According to the similarity criterion,the experiment model was established,simi-lar to the real geometry,model size and real size ratio of 1:5 .And the high accuracy of elbow flowmeter was installed for flow measurement in each line.According to the statistical analysis of experimental data, the sum of each branch measurement of flow rate is very consistent with the true value,accuracy at 1%level.The numerical simulation results show that Branch flow rate and flow of average value deviation in ± 1% range,When the size precision of key structure is strictly controlled in the device.By selecting 4 branch as the measured position of elbow flowmeter,then the ideas on the realization of accurate assessment of 14 pipeline total flow is feasible.