Criteria for Performing White Blood Cell Differential Count

孙芾,王厚芳,林宏,穆煜,柳杰,杜振波
DOI: https://doi.org/10.3969/j.issn.1674-1129.2004.04.002
2004-01-01
Abstract:Objective To find a proper way for accurate reports on complete blood counts(CBC). Methods The criteria for blood cell microscopic examination was set up according to patient data; 1128 blood specimens were analyzed according to the criteria, and statistics on the data were made to find out the reliability of the procedures. Results There were 31% of CBC specimens needed for microscopic examination, of which 33% had increased bands or increased atypical lymphocytes or other abnormalities. Conclusions It is very important to set up the criteria for performing peripheral blood smear. It can provide more accurate and reliable information to clinical doctors.
What problem does this paper attempt to address?