Locking Looped Suture: a Biomechanical Study in Vitro

王斌,汤锦波,陈峰,谢仁国,于晓巍,吴菊
DOI: https://doi.org/10.3969/j.issn.1671-2722.2001.01.012
2001-01-01
Abstract:Objective The study is to compare four kinds of locking looped suture techniques. Methods Fourty porcine flexor profundus tendons were transected in zone II and divided into four groups. Tendons of each group were repaired by one of the following locking looped suture techniques: Strickland, Augmented Becker, Savage and Tang. 2mm gap formation force, failure load, elastic modulus and energy to break point were tested by a material testing machine. Operation time of core suture was also recorded. Results Tang was similar to Savage in 2mm gap formation force, failure load and energy to break point, superior to other three techniques in elastic modulus. Its operated time was also less than Savage and Augmented Becker. Conclusion Tang's suture technique was of the first choice because it can offer reliable tensile strength, fight against gap formation effectively and was easy to operate.
What problem does this paper attempt to address?