Abstract:In the top drive device,rotary head lug tensile,impact loading is bigger,its security can-not be ignored.Therefore,the 3 150 kN grade top drive turned back lug for stress testing and fi-nite element analysis calculating,stress test results are agreement with a finite element calcula-tions.The results indicate that the dangerous position are situated in the rotary head hanging ear root and the rotary head lug and the ring contact place ,the results of the turret lifting lug struc-ture design,safety inspection,safety evaluation have some reference value.
What problem does this paper attempt to address?