OCCURRENCE AND DISTRIBUTION OF LEGIONELLA IN MAN-MADE WATER SYSTEMS OF GUANGZHOU

施海琼,黄炯威,吴夏飞,林尤海,徐润林,周世宁,陆勇军
DOI: https://doi.org/10.3321/j.issn:1006-687X.2003.06.017
2003-01-01
Chinese Journal of Appplied Environmental Biology
Abstract:Legionella are opportunistic pathogens which normally live in water,in soil and within free-living unicellular protozoa and can cause pneumonia known as Legionnaires' disease which has been reported frequently all over the world since 1980's. To investigate the occurrence and distribution of Legionella in Guangzhou,a combination of plating isolation,seminested PCR and EnviroAmp PCR reverse hybridization kit was used to isolate and detect the Legionella from man-made water systems which were proved to be the source of infectious aerosols contaminated with Legionella . The seminested PCR results showed that the positive rate of the samples from water-cooling towers was 84% in average,even up to 100% in 3 of 9 sampling sites. The positive rate of tape water was 35%,though L. pneumophila was not found. These results demonstrate high Legionella -contaminating degree in Guangzhou man-made water systems, although the positive rate slightly fluctuates along with the sampling time and places. The disadvantage and advantage of each detective method used in this research,and seasonal occurrence and distribution of Legionella are also discussed in this paper. Fig 2,Tab 2,Ref 16