TEST AND STUDY ON TEMPERATURE FIELD OVER CROSS-SECTION OF LARGE-SCALE BOILER

姚斌,娄春,刘浩,周怀春,陈士英,邵主建,庄群,郑见云
DOI: https://doi.org/10.3969/j.issn.1002-3364.2003.09.008
2003-01-01
Abstract:The flame image in the furnace of a largescale boiler has been detected by using four CCD flame detectors. Through processing of the flame image, the detection of temperature distribution over the furnace cross-section of a boiler has been realized, giving the temperature distribution over said cross-section under various operation conditions, and the results being analysed and compared. The results of furnace temperature field created by the flame image show that the temperature field over the cross-section above the zone of burners appears as a typical single-peak distribution character, and its skewness is basically consistent with the operational experience in the said power plant.
What problem does this paper attempt to address?