Structure and depth profile composition analysis of Cr/(B4C)/V/(B4C) multilayer for water window application

Pin Li,Qiushi Huang,Li Jiang,Wenbin Li,Jiani Fei,Jie Zhu,Zhong Zhang,Zhanshan Wang
DOI: https://doi.org/10.1016/j.vacuum.2016.02.014
IF: 4
2016-01-01
Vacuum
Abstract:Ultrathin B4C barrier layers have been recently used to reduce the interface widths of soft X-ray Cr/V multilayers and improve the reflectance at the water window region. To further study the chemical changes in the multilayer induced by the barrier layers, Cr/V multilayers (period equals to 4 nm) with and without B4C barrier layers were characterized by grazing incidence X-ray reflectometry (GIXR) and X-ray photoelectron spectroscopy (XPS). The GIXR results show that the B4C barrier layers significantly reduce the interface widths of the 4 nm-period Cr/V multilayer as already observed for the short-period multilayer. The XPS depth profile confirms an enhanced elemental contrast between Cr and V in the multilayer with B4C, as compared to the one with no barriers. According to the fitting results of the photoelectron peaks, the compound formation of VB2, extra VC and B4C were found in the structure with barrier layers. These compounds help suppress the interdiffusion between Cr and V and contribute to the small interface widths of the multilayer.
What problem does this paper attempt to address?