Removal of Iron, Manganese and Ammonia from Groundwater Using a PAC-MBR System: the Anti-Pollution Ability, Microbial Population and Membrane Fouling

Xing Du,Guangyang Liu,Fangshu Qu,Kai Li,Senlin Shao,Guibai Li,Heng Liang
DOI: https://doi.org/10.1016/j.desal.2016.03.002
IF: 11.211
2016-01-01
Desalination
Abstract:Iron, manganese and ammonia are common inorganic pollutants in groundwater. In the current study, a powdered activated carbon-amended membrane bioreactor (PAC-MBR) was designed for the treatment of groundwater (approximately Mn2+1.2mg·L−1, Fe2+=15.0mg·L−1 and NH4+-N=2.2mg·L−1). Two lab-scale PAC-MBR systems were implemented to operate for 220 d to purify three influents that had different levels of pollutants, including raw water and the effluent of conventional bio-sand filters with different dissolved oxygen levels (i.e., 9mg·L−1 and 6mg·L−1) before filtration. The results showed that an excellent MBR effluent (iron<0.2mg·L−1, manganese<0.1mg·L−1 and ammonia<0.05mg·L−1) was obtained irrespective of the amount of pollutants, but the start-up period varied (20–49d). With respect to the trans-membrane pressure (TMP) evolution, system I (PVDF) exhibited good performance with a slight TMP increase from 7.0 to 17.0kPa, whereas system II (PVC) exhibited a sharp rise from 20.0 to 60.0kPa. In brief, a cake layer containing PAC and oxides was the main reason for membrane fouling. High-throughput sequencing analysis revealed that Mn-oxidizing bacteria (MnOB) (i.e., Leptothrix, Pseudomonas, Hyphomicrobium and Planctomyces) and ammonia-oxidizing bacteria (AOB) (i.e., Nitrospira, Nitrosomonas) played major roles in the PAC-MBR systems.
What problem does this paper attempt to address?