Anti-fouling Characteristic of Carbon Nanotubes Hollow Fiber Membranes by Filtering Natural Organic Pollutants

Yue Yang,Sen Qiao,Ruofei Jin,Jiti Zhou,Xie Quan
DOI: https://doi.org/10.1007/s11814-017-0354-0
IF: 2.7
2018-01-01
Korean Journal of Chemical Engineering
Abstract:Membrane fouling is a universal problem for conventional membrane filtration that usually causes a deterioration in membrane performance. We used electro-assisted carbon nanotubes hollow fiber membranes (CNTs-HFMs) to investigate the anti-fouling properties using natural organic pollutants. Benefiting from the electro-assistance, the permeation flux of humic acid solution using CNTs-HFMs was 190.20 L/(m2·h·bar), which was about 1.5- and 4.4-times higher than those of CNTs-HFMs without electro-assistance and traditional polyvinylidene fluoride hollow-fiber membranes (PVDF-HFMs). And the permeation fluxes of bovine serum albumin, sodium alginate and supernatant of anaerobic bioreactor also presented similar results. The average COD removal rate of CNTs-HFMs (66.8%) at −1.0 V was higher than that of CNTs-HFMs without electro-assistance and PVDF-HFMs, which can be attributed to the formation of electrostatic repulsive force. It could reduce the deposition of pollutants on membrane surface under electroassistance.
What problem does this paper attempt to address?