Investigation on the Influence of Different Heat Transmission Distances on Thermo-Hydrodynamic Characteristics of Pulsating Heat Pipes
Ying Liu,Kangli Bao,Yuhao Yan,Hongshen Ouyang,Xiaohong Han
DOI: https://doi.org/10.1016/j.applthermaleng.2023.121284
IF: 6.4
2023-01-01
Applied Thermal Engineering
Abstract:Pulsating heat pipe (PHP) exhibits potential as a high-heat-flux heat sink in various thermal applications. It is crucial to understand the impact of heat transmission distance on the thermo-hydrodynamic characteristics of PHP since the heat transmission distance differs in various applications. In this paper, the start-up, flow, and heat transfer performance and anti-dry-out capacity of PHPs with different heat transmission distances (130 mm, 500 mm, 1000 mm, and 1500 mm) were experimentally investigated. The experimental results indicated that at low heat input, the start-up performance of the PHP deteriorated significantly as the heat transmission distance increased. The peak temperature of the evaporation section (Ts, max) was high and the start-up time was long for the PHP with a long heat transmission distance. As the heat transmission distance grew, the flow performance of the PHP also deteriorated, and more heat was needed to convert the flow regime from oscillation at intervals to oscillation without stagnation. The thermal resistance increased significantly with the growth of the heat transmission distance at the range of 5 W-50 W, while the thermal resistances under different heat transmission distances were close at the range of 60-100 W. As the heat transmission distance grew, the anti-dry-out capacity initially rose and subsequently fell. So there was an optimal heat transmission distance that made the PHP have the finest anti-dry-out capacity. What's more, the heat transmission distance of 1500 mm was approximately equal to the limit heat transmission distance for the PHP in this work.