Effect of Particle Size Distribution on Concentration Measurement With Light Extinction Method

cui jiang,liu xiaowei,chen dong,xu yishu,han jinke,xu minghou
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.160360
2016-01-01
Abstract:Particulate matter(PM) emission of coal-fired power plant is one of the main factors that cause environmental pollution, So on-line monitoring of the PM concentration is of great importance.A MATLAB program was developed based on light scattering theory to study the relationship between the extinction coefficient and the size and complex refractive index of the particle. Moreover, the relationship between the particle concentration and the extinction curve was also studied. Then a self-designed particle concentration measuring device was built in the laboratory and calibrated with two standard particle samples. Three spherical silicon dioxide with different size distributions were used to investigate the impact of particle size distribution on the concentration measurement. The results show that the measurement deviation is increases with the fraction of particle with the dimensionless size factor α>30 in the sample.
What problem does this paper attempt to address?