Experimental study on particle size distributions of lead particulate matters during combustion

ZHANG Xiaofeng,ZHUO Jiankun,SONG Qiang,YAO Qiang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2007.08.024
2007-01-01
Abstract:A 3.4 m tall,0.15 m inside diameter,one-dimension furnace was used to study the particle size distributions of lead particles during combustion.An aqueous solution of lead acetate was introduced into the furnace through a liquefied petroleum gas flame via air atomization.The mass distribution and number distribution were obtained using an 8-stage Andersen Impactor with aerodynamic cut-off diameters from 0.48 to 12.63 μm and a 12-stage electrical low pressure impactor(ELPI) with aerodynamic cut-off diameters from 0.03 to 10.0 μm.The lead particle microstructures were analyzed using a field emission scanning electron microscope.The results indicate that for the mass concentration measurements,the majority of the lead particles are submicron particles,with a peak at 0.2-0.6 μm.For the number concentration measurements,the majority of the lead particles have sizes of 0.03-0.4 μm,with a peak at 0.2-0.3 μm.
What problem does this paper attempt to address?