On-line measurement of coal powder size distribution using digital holography

Liang ZHAO,Chenyue WU,Xiaodan LIN,Yingchun WU,Xuecheng WU,Yonggang ZHOU,Kunzan QIU,Kefa CEN
DOI: https://doi.org/10.11949/j.issn.0438-1157.20171242
2018-01-01
Abstract:Particle size distribution of coal powder is one of the most important indexes which contribute a lot to energy conservation and emission reduction of power plant. Digital holography is applied to measure the particle size distribution on a set of device stimulating the actual working conditions of coal supply system of power station. The results show that the distribution curve measured by digital holography has the similar trend with the curve measured by laser particle size analyzer. The relative error between the average diameters is 5.6%. The relative errors between the d50and d90, are less than 2% which is in the allowable range. The relative errors between before and after the dilution is lower than 7%. The trends of particle size distribution curve of the same sample are consistent in different conditions. The reliability of digital holography for on-line measurement of pulverized coal particle size distribution is verified, which lays a foundation for the development of the overall measurement instrument.
What problem does this paper attempt to address?