Experimental Study of the γ-ray Method for Measuring the Gas Content in a Cross Section with a Subcritical Steam-water Two-phase Flow

hu richa,liu chunlong,bi qincheng,lv haicai
DOI: https://doi.org/10.16146/j.cnki.rndlgc.2015.06.004
2015-01-01
Abstract:By adopting a single narrow beam γ-ray method,the void fraction in a section featuring a subcritical steam-water two-phase flow in a vertical riser was measured. The operating conditions in the riser were given as follows: the pressure ranged from 17 MPa to 21 MPa,the mass flow speed of the working medium was in a range from 600 kg /( m2·s) to 1 000 kg /( m2·s) and the temperature fell in a range from 25 ℃ to 400 ℃. Through an analysis,the feasibility to measure the void fraction in a section of a subcritical steam-liquid two-phase flow by adopting the γ-ray method was investigated and the influence of the mass flow rate,pressure and temperature of the working medium on the measurement results by using the γ-ray method was also analyzed. It has been found that the mass flow rate and pressure of the working medium will have almost no influence on the measurement of the void fraction in a section of a subcritical steam-liquid two-phase flow by adopting the gamma-ray method while a change in the temperature by a great margin will exercise a relatively marked influence on the measurement. A comparison of the test and measurement values with those calculated by using the classic theoretical formula shows that the test and measurement values are in very good agreement with those calculated by using the Smith formula.